wet venting diagrams

Author

Sophia Vance

Updated on July 28, 2026

There are different wet venting systems that both model and state plumbing codes allow. Vertical and horizontal wet vents are the most common of all these systems.

What is the code for a wet vent?

908.2 Horizontal Wet Venting for a Bathroom Group.

What is horizontal wet venting?

The wet vent shall be considered the vent for the fixtures and shall extend from the connection of the dry vent along the direction of the flow in the drain pipe to the most downstream fixture drain connection to the horizontal branch drain.

How far can you run a wet vent?

The wet vent portion, from the vent connection at the sink to the wye that connects the toilet has no distance limit (it actually goes vertical). The portion from the vent connection to the sink is limited by the grade of the pipe (distance will vary as the pipe could be 2″, 1-1/2″, or 1-1/4″ for a bathroom sink).

What is the minimum size of a wet vent?

Any wet vents must be 2 in. minimum in diameter.

How many fixtures can you wet vent?

A horizontal wet vent could have as few as two fixtures or as many as ten fixtures but not more than two fixtures of any type can be connected to the system. Each wet vented fixture drain shall connect independently to the horizontal wet vent.

How far can vent be from shower drain?

The maximum distance from a shower trap arm to a vent is usually 5 feet, though some municipalities may allow up to 8 feet.

Does a plumbing vent have to go straight up?

Plumbing vents need to be straight on the vertical. This is necessary to avoid any vapor locks from occurring. When there is a bend in the vent pipe, moisture accumulates and is trapped.

How many fixture units can a 2 inch wet vent handle?

There can be 24 fixture units on a 2-inch vent according to national building regulations.

Can a shower and sink share a vent?

You can put the sink drain into the shower drain. 2. If the vent is less than 5 feet from the other fixture, they can share it.

How far can a vent run horizontal?

If you have 1- 1/4-inch pipe, the horizontal distance of the vent ought to not be more than 30 inches. For a 1- 1/2-inc pipe the vent must be 42 inches away at the most while a 2-inch pipeline must have an optimum distance of 5 feet.

How many fixture units does a 3 inch wet vent have?

A 3-inch (76 mm) soil stack with a stack vent serving as the required vent extension to the outdoors, connecting to a 3-inch (76 mm) building drain, must have at least a 1½-inch (38 mm) stack vent [maximum of 102 fixture units served and a maximum 25-foot (7620 mm) developed length] in accordance with Section 906.1 and

Can a plumbing vent go out a wall?

You can pass the vent through a wall instead of through the roof, but it must still rise over the roof.

How close to the toilet does the vent need to be?

According to the UPC, the distance between your trap and the vent should be no more than 6 feet. In other words, for the vent to work properly, it needs to feed into the drain line within 6 feet of the trapways that connect to it.

How high above the roof should a vent pipe be?

Unless a roof is to be used for any purpose other than weather protection, extensions of vent pipes through a roof should be terminated at least 12 inches above the roof. The vent should be extended at least seven feet above the roof if it is to be used for something other than weather protection.

Can you vent a toilet with a 2 inch pipe?

Toilet vent pipes are usually configured by feeding a 2-inch PVC pipe within the wall in back of the toilet down from the ceiling. This pipe connects right into the toilet drain pipe. Then, the tub/shower drain pipe and sink drain pipe are vented with 1.5-inch pipe, and these branch off the toilet pipe.